Будь ласка, використовуйте цей ідентифікатор, щоб цитувати або посилатися на цей матеріал: http://repositsc.nuczu.edu.ua/handle/123456789/12319
Повний запис метаданих
Поле DCЗначенняМова
dc.contributor.authorAI Kovalov, Отрош Юрій Анатолійович, TM Kovalevska, SO Safronov-
dc.date.accessioned2021-01-05T06:55:13Z-
dc.date.available2021-01-05T06:55:13Z-
dc.date.issued2019-12-
dc.identifier.citationIOP Conference Series: Materials Science and Engineeringru_RU
dc.identifier.urihttp://repositsc.nuczu.edu.ua/handle/123456789/12319-
dc.description.abstractIn the work, the tests have been analysed for fire-resistant quality of hollow-core reinforced-concrete floors with fire-retardant plaster covering. A two-dimensional physical model and computer model have been developed in the ANSYS FLUENT software environment, which includes a system of equations and boundary conditions, taking into account the thermal conductivity in the coating and concrete, as well as complex convection-radiation heat transfer in air voids. A one-dimensional multilayer mathematical model has been developed, equivalent to a two-dimensional model of the thermal state of hollow-core reinforced-concrete floor with fire-retardant plaster covering, with the specific these layers’ thicknesses. A methodology has been developed in the article, based on solving the direct and inverse heat conduction problems, with the help of which it is possible to assess the fire-resistant quality of hollow-core reinforced-concrete floors with and without fire-retardant coatings. The developed methodology was applied to determine the thermophysical (heating constant and specific heating capacity per unit volume) and fire-retardant characteristics of the studied plaster covering according to the results of tests for fire-resistant quality of reinforced-concrete floors with this fire-retardant coating. The conclusion was made about the effectiveness of this coating and the boundaries of using the fire-retardant coatings to ensure normalizable values for the limit of the fire-resistant quality of hollow-core reinforced-concrete floorsru_RU
dc.language.isoenru_RU
dc.publisherIOP Publishingru_RU
dc.relation.ispartofseries708;012058-
dc.titleMethodology for assessment of the fire-resistant quality of reinforced-concrete floors protected by fire-retardant coatingsru_RU
dc.typeArticleru_RU
Розташовується у зібраннях:Кафедра пожежної профілактики в населених пунктах

Файли цього матеріалу:
Файл Опис РозмірФормат 
Kovalov_2019_IOP_Conf._Ser.__Mater._Sci._Eng._708_012058.pdf904,09 kBAdobe PDFПереглянути/Відкрити


Усі матеріали в архіві електронних ресурсів захищені авторським правом, всі права збережені.