Будь ласка, використовуйте цей ідентифікатор, щоб цитувати або посилатися на цей матеріал: http://repositsc.nuczu.edu.ua/handle/123456789/13365
Повний запис метаданих
Поле DCЗначенняМова
dc.contributor.authorIurchenko, V.-
dc.contributor.authorSierohlazov, V.-
dc.contributor.authorMelnikova, O.-
dc.contributor.authorBryhada, O.-
dc.contributor.authorMykhailova, L.-
dc.date.accessioned2021-07-14T07:34:51Z-
dc.date.available2021-07-14T07:34:51Z-
dc.date.issued2021-07-
dc.identifier.citationIurchenko V., Sierohlazov V., Melnikova O., Bryhada O., Mykhailova L. Hydrogen Sulphide in Industrial Enter-prises Water Management Infrastructure - The Factor of Chemical and Microbiological Corrosion Concrete Degradation of Water Facilities / Problems of Emergency Situations: Materials and Technologies II. Materials Science Forum. Vol. 1038. 2021. P. 401-406.ru_RU
dc.identifier.issn1662-9752-
dc.identifier.urihttp://repositsc.nuczu.edu.ua/handle/123456789/13365-
dc.descriptionIurchenko V., Sierohlazov V., Melnikova O., Bryhada O., Mykhailova L. Hydrogen Sulphide in Industrial Enter-prises Water Management Infrastructure - The Factor of Chemical and Microbiological Corrosion Concrete Degradation of Water Facilities / Problems of Emergency Situations: Materials and Technologies II. Materials Science Forum. Vol. 1038. 2021. P. 401-406.ru_RU
dc.description.abstractThe durability of concrete, the material which is widely used for water facilities depends on accumulation in operational environments (drain water, air-gas space) of hydrogen sulfide. Now the mechanism of corrosion destruction of concrete in drainage pipelines is represented as result of biogenous sulphuric acid aggression – influence of the sulphuric acid formed by thionic bacteria. The analysis of data on H 2 S concentration in drain waters of various industrial enterprises demonstrates that they create in gaseous operational media H 2 S concentration, sufficient for development in aerobic conditions of thionic bacteria. As the results of urban sewer networks inspection have shown, the correlation between concentration of H 2 S in aqueous phase and its concentration in air environment, between concentration of H 2 S in air environment and the corrosion rate of concrete’s coffering part is observed. Chemical and X-ray crystallography of this concrete showed that in corrosive concrete decreases pH, reaching in some examples of values 1-2, and sulfates collect. In dynamics of corrosion process the exponential growth of concentration in concrete of extremely acidophilic thionic bacteria is noted.ru_RU
dc.language.isoenru_RU
dc.publisherTrans Tech Publications Ltd, Switzerlandru_RU
dc.subjectconcreteru_RU
dc.subjectwater management industryru_RU
dc.subjectdrainageru_RU
dc.subjecthydrogen sulfideru_RU
dc.subjectcorrosionru_RU
dc.subjectbiogenous sulphuric acid aggression.ru_RU
dc.titleHydrogen Sulphide in Industrial Enter-prises Water Management Infrastruc-ture - The Factor of Chemical and Microbiological Corrosion Concrete Degradation of Water Facilitiesru_RU
dc.typeArticleru_RU
Розташовується у зібраннях:Кафедра охорони праці та техногенно-екологічної безпеки

Файли цього матеріалу:
Файл Опис РозмірФормат 
MSF.1038.401.pdf426,02 kBAdobe PDFПереглянути/Відкрити


Усі матеріали в архіві електронних ресурсів захищені авторським правом, всі права збережені.