Будь ласка, використовуйте цей ідентифікатор, щоб цитувати або посилатися на цей матеріал: http://repositsc.nuczu.edu.ua/handle/123456789/20474
Повний запис метаданих
Поле DCЗначенняМова
dc.contributor.authorПетухова, Елена Анатольевна-
dc.date.accessioned2024-08-06T06:34:06Z-
dc.date.available2024-08-06T06:34:06Z-
dc.date.issued2024-
dc.identifier.citationPospelov, B., Krainiukov, O., Bezuhla, Y., Petukhova, O., Melnychenko, A., Bogatov, O., Holovchenko, S., Nepsha, O.,Yesipova, O., Tishechkina, K. (2024). Ignition detection method based on real-time measurements of a hazardous parameter in the environment. Eastern-European Journal of Enterprise Technologies, 3 (10 (129)), 42–49. https://doi.org/10.15587/1729-4061.2024.306709uk_UA
dc.identifier.urihttp://repositsc.nuczu.edu.ua/handle/123456789/20474-
dc.description.abstractThe object of this study is a selective average of the dangerous parameters of the gas environment during the ignition of materials. Theoretical substantiation of the fire detection method based on testing the null hypothesis regarding the current difference of the specified selective averages of an arbitrary dangerous parameter of the gas environment has been performed. In this case, the significance of the current difference with respect to selective averages allows detection of ignition in real-time observation of an arbitrary dangerous parameter of the gas environment. The method makes it possible to set the level of significance for the current difference and at the same time provide for the maximum power of fire detection. Laboratory experiments were conducted to verify the proposed method for detecting ignition based on the current difference of the selective averages of the measured dangerous parameters of the gas environment corresponding to the training and control general population. The results of verification showed that at a given level of significance, the method allows detecting current fires of materials based on significant differences in sample means. It was established that the current difference in the concentration of carbon monoxide during ignition and after ignition of alcohol, paper, wood shavings, and textiles is –0.459 and 8.296, –0.152 and 4.299, –0.027 and 6.9, –0.262 and 2.3, respectively. Current smoke density differences are 0.043 and 0.391, 0.012, and 0.923, –0.139, and –0.235, 0.034, and 0.129, and temperatures are –0.01 and 10.635, 0.53 135 and 2.726, respectively.uk_UA
dc.language.isoenuk_UA
dc.publisherНПП ЧП «Технологический Центр». Eastern-European Journal of Enterprise Technologiesuk_UA
dc.titleIgnition detection method based on real-time measurements of a hazardous parameter in the environmentuk_UA
Розташовується у зібраннях:Кафедра пожежної профілактики в населених пунктах

Файли цього матеріалу:
Файл Опис РозмірФормат 
Петухова-червень 2024.pdf1,19 MBAdobe PDFПереглянути/Відкрити


Усі матеріали в архіві електронних ресурсів захищені авторським правом, всі права збережені.