Будь ласка, використовуйте цей ідентифікатор, щоб цитувати або посилатися на цей матеріал: http://repositsc.nuczu.edu.ua/handle/123456789/21088
Повний запис метаданих
Поле DCЗначенняМова
dc.contributor.authorСтась, Сергій Васильович-
dc.contributor.authorБиченко, Артем Олексійович-
dc.contributor.authorКолесніков, Денис Валерійович-
dc.contributor.authorМигаленко, Олексій Іванович-
dc.contributor.authorПустовіт, Михайло Олександрович-
dc.contributor.authorМигаленко, Костянтин Іванович-
dc.contributor.authorГоренко, Леся Михайлівна-
dc.date.accessioned2024-10-21T07:29:03Z-
dc.date.available2024-10-21T07:29:03Z-
dc.date.issued2023-06-30-
dc.identifier.citationEastern-European Journal of Enterprise Technologies, 3(1 (123), 13–20.uk_UA
dc.identifier.urihttp://repositsc.nuczu.edu.ua/handle/123456789/21088-
dc.description.abstractThe phenomenon of changing the geometric parameters of pressure fire hoses is manifested when they transport extinguishing liquids. Although the extension of pressure fire hoses does not have a significant impact on the fire extinguishing process, the energy costs associated with such changes should be taken into account. In fact, part of the power of the fire pump is spent not on transporting liquids and forming extinguishing jets but on the «optional» lengthening of pressure fire hoses. Latex pressure fire hoses with diameters of 51 mm and 77 mm and fire pressure hoses with double-sided polymer coating of 51 mm (all of type T) were randomly selected for the experiments. The temperature was 263 K and 298 K, the fluid flow rate was constant, the pressure values at the inlet of the Protek 366 fire barrel had fixed values. No significant changes in the diameters (expansion or narrowing) of pressure fire hoses were recorded during water transportation. An elongation of 79 cm with a hose length of 1960 cm (73 cm with a hose length of 1790 cm) was recorded when transporting water in the case of using hoses with a diameter of 77 mm, a pressure at their inlet of 0.8 MPa, a temperature of 263 K, and a water flow rate of 0 l/s. The force that provided such a stretch was 2.04 kN. When extinguishing liquid was supplied by pressure fire hoses with a diameter of 77 mm in the temperature range of 263–298 K, the elongation decreased slightly with decreasing temperature. A slight unevenness of stretching of pressure fire hoses along the length was found when stretching increased closer to their middle. The results indicate the dependence of the amount of stretching on the materials from which pressure fire hoses are made, as well as their diameter. The values of dynamic forces that cause stretching of pressure fire hoses established in the study can be used in practice when taking into account the forced energy losses for fluid transportationuk_UA
dc.language.isoenuk_UA
dc.publisherEastern-European Journal of Enterprise Technologiesuk_UA
dc.relation.ispartofseriesVol. 3 No. 1 (123) (2023): Engineering technological systems;-
dc.subjectfire hose, hose line, water transportation, geometric dimensions, fire hose extensionuk_UA
dc.titleDetermining the elongation of T-type pressure fire hoses based on full-scale experimentsuk_UA
dc.typeArticleuk_UA
Розташовується у зібраннях:ЧІПБ ім. Героїв Чорнобиля

Файли цього матеріалу:
Файл Опис РозмірФормат 
279616-Article Text-651881-1-10-20230624.pdf2,75 MBAdobe PDFПереглянути/Відкрити


Усі матеріали в архіві електронних ресурсів захищені авторським правом, всі права збережені.