Будь ласка, використовуйте цей ідентифікатор, щоб цитувати або посилатися на цей матеріал:
http://repositsc.nuczu.edu.ua/handle/123456789/28460Повний запис метаданих
| Поле DC | Значення | Мова |
|---|---|---|
| dc.contributor.author | Melnychenko | - |
| dc.contributor.author | Shakhov | - |
| dc.contributor.author | Vynohradov | - |
| dc.contributor.author | Hryschenko | - |
| dc.contributor.author | Knaub | - |
| dc.contributor.author | Maslich | - |
| dc.contributor.author | Mohylianets | - |
| dc.contributor.author | Pinder | - |
| dc.contributor.author | Pavlyuk | - |
| dc.date.accessioned | 2026-06-09T13:18:55Z | - |
| dc.date.available | 2026-06-09T13:18:55Z | - |
| dc.date.issued | 2025-12-31 | - |
| dc.identifier.citation | Eastern-European Journal of Enterprise Technologies | uk_UA |
| dc.identifier.uri | http://repositsc.nuczu.edu.ua/handle/123456789/28460 | - |
| dc.description.abstract | his study examines the fire extinguishing efficiency of aqueous fire extinguishing agents such as compressed air foam with a modified NH4H2PO4 additive, compressed air foam of standard composition, water, and gel-forming composition.The principal hypothesis assumes that com-pressed air foam with a modified NH4H2PO4additive has more effective fire extinguishing properties when extinguishing class A fires in comparison with compressed air foam of stan-dard composition, water, and gel-forming com-positions.The task addressed was predetermined by the lack of scientifically substantiated com-parative data on the fire extinguishing effi-ciency of aqueous fire extinguishing agents when extinguishing standardized model fires of class 1A: compressed air foam with a mod-ified NH4H2PO4 additive, compressed air foam of standard composition, water, and gel-form-ing composition.When using all of the above fire extinguish-ing agents, successful elimination of combus-tion was observed. However, the lowest time and mass spent on extinguishing were estab-lished precisely for CAF with MA NH4H2PO4. The mass spent on extinguishing the fire by the CAF with NH4H2PO4 is 7% less than the mass of the CAF of standard composition and 52% less than the mass of water. For compressed air foam with MA NH4H2PO4, the extinguish-ing time was recorded to be 10% less than the time required to extinguish the fire by the CAF of standard composition and 51% less than the time of extinguishing with water.The extinguishing efficiency indica-tors of the CAF with MA NH4H2PO4, CAF of standard composition, GFC, and water were compared with each other. As a result, the indicator for CAF with MA NH4H2PO4is Іе.e=16. 5m2/kg∙s; for CAF of standard composition, Іе.e=14.03m2/kg∙s; for GFC, Іе.e=11.9m2/kg∙s; for water, Іе.e=3.94m2/kg∙s.The results emphasize that the use of MA in the composition of CAF, in particu-lar NH4H2PO4, increases its fire-extinguishing properties when extinguishing class A fires. It has been proven that the fire-extinguishing efficiency of CAF with MA content is 15% high-er compared to CAF of standard composition. Compared to GFC, the efficiency is 28% higher; compared to water, 77% higher | uk_UA |
| dc.language.iso | en | uk_UA |
| dc.relation.ispartofseries | 6(10(138)); | - |
| dc.subject | compressed air foam | uk_UA |
| dc.subject | modified additives | uk_UA |
| dc.subject | fire-extinguishing properties, | uk_UA |
| dc.subject | class A fires | uk_UA |
| dc.title | Determining the fire extinguishing efficiency of compressed air foam with modified additive NH4H2PO4 | uk_UA |
| dc.type | Article | uk_UA |
| Розташовується у зібраннях: | Кафедра організації і проведення аварійно-рятувальних робіт | |
Файли цього матеріалу:
| Файл | Опис | Розмір | Формат | |
|---|---|---|---|---|
| 345244-Article Text-809589-1-10-20251231.pdf | 1,27 MB | Adobe PDF | Переглянути/Відкрити |
Усі матеріали в архіві електронних ресурсів захищені авторським правом, всі права збережені.