Please use this identifier to cite or link to this item:
http://repositsc.nuczu.edu.ua/handle/123456789/21199
Title: | Influence of the fire temperature regime on the fire-retardant ability of reinforced-concrete floors coating |
Authors: | Kovalov A., Otrosh Y., Semkiv O., Konoval V., Chernenko O. |
Keywords: | hollow-core reinforced-concrete floors, fire-resistant quality, fire-retardant coating, fireretardant ability, temperature regime of the fire |
Issue Date: | 2020 |
Publisher: | Trans Tech Publications Ltd. In Materials Science Forum |
Series/Report no.: | Volume 1006.;P. 87–92 |
Abstract: | In the paper, the tests have been analysed for fire-resistant quality of the hollow-core reinforced-concrete floors with fire-retardant plaster covering under standard temperature regime of the fire. Using the methodology for determining the characteristics of fire-retardant coatings ability for reinforced-concrete floors, the dependences have been obtained of the fire-retardant coating thickness from the concrete protective layer of a hollow-core reinforced-concrete floor for a fire resistance limit of 180 minutes with a temperature regime of hydrocarbon fire and a tunnel curve according to the Netherlands standards (RWS). It has been concluded about the minimum required thickness of the studied fire-retardant coating to provide the required fire resistance limit of a hollow-core reinforced-concrete floor under the indicated fire regimes |
URI: | http://repositsc.nuczu.edu.ua/handle/123456789/21199 |
ISSN: | 1662-9752 |
Appears in Collections: | ЧІПБ ім. Героїв Чорнобиля |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
MSF.1006.87.pdf | 365,5 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.