Please use this identifier to cite or link to this item:
http://repositsc.nuczu.edu.ua/handle/123456789/21332
Title: | A Method of Evaluating the Destruction of a Reinforced Concrete Hollow Core Slab for Ensuring Fire Resistance |
Authors: | Березовський, Андрій Іванович Сідней, Станіслав Олександрович Костенко, Тетяна Вікторівна |
Keywords: | finite element modeling; temperature distribution; uniformly distributed load; weight reduction |
Issue Date: | 2023 |
Publisher: | Sumy State University |
Citation: | Journal of Engineering Sciences (Ukraine) |
Series/Report no.: | Volume 10, Issue 2; |
Abstract: | Fire tests of reinforced concrete floor slabs do not allow the detection of the onset of the boundary state due to loss of entirety because blocks are installed on the unheated surface to reproduce the design load. This prevents the formation of cracks through which toxic combustion products, smoke, and temperature spread can penetrate. Determining a building structure’s actual fire resistance limit was fixed at the onset of any fire resistance boundary state. It was proven that calculation methods for fire resistance assessment have significant advantages over experimental methods. To reduce the number of finite elements for a rational calculation of the fire resistance assessment of a reinforced concrete hollow core slab, a geometric model of 1/4 of this structure was built. The possibility of visualizing the studied structure at full scale was realized when obtaining the calculation results. The stress-strain state of the studied structure was evaluated based on the thermal and mechanical loading results applied to the reinforced concrete hollow core slab. Thus, the work’s objective was achieved based on the calculation experiments’ results. A methodology was developed for calculating the destruction of a reinforced concrete hollow core slab while assessing its fire resistance. Scientific fundamentals for determining the onset of the boundary state of loss of entirety were developed. The proposed methodology allowed for a reliable assessment of the fire resistance of such structures. © 2023, Sumy State University. All rights reserved. |
URI: | http://repositsc.nuczu.edu.ua/handle/123456789/21332 |
Appears in Collections: | ЧІПБ ім. Героїв Чорнобиля |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
scopusresults (1).pdf | 60,9 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.