Будь ласка, використовуйте цей ідентифікатор, щоб цитувати або посилатися на цей матеріал: http://repositsc.nuczu.edu.ua/handle/123456789/25676
Повний запис метаданих
Поле DCЗначенняМова
dc.contributor.authorНекора, Ольга Валеріївна-
dc.contributor.authorПоздєєв, Сергій Валерійович-
dc.contributor.authorШналь, Тарас Миколайович-
dc.contributor.authorЯковчук, Роман-
dc.date.accessioned2025-09-30T06:33:19Z-
dc.date.available2025-09-30T06:33:19Z-
dc.date.issued2020-08-
dc.identifier.citationLecture Notes in Civil Engineeringuk_UA
dc.identifier.isbnart of ISBN: 9783030573393-
dc.identifier.issnPart of ISSN: 23662557 23662565-
dc.identifier.urihttp://repositsc.nuczu.edu.ua/handle/123456789/25676-
dc.description.abstractThe purpose of the work was to develop a mathematical model of fire spreading in a three-story building during full-scale fire-response tests; research of accuracy and reliability of parameters of temperature modes of fire in separate premises of the building. The Pyrosim computer system, a user shell for the Fire Dynamics Simulator program, was used to calculate the temperature in the models of premises under fire. A numerical experiment was conducted to model full-scale tests of premises with fire in a three-story building using computer gas-hydrodynamics methods. The nature of the fire development and the time dependences of its main parameters were revealed, which in turn allowed analyzing the adequacy of the modelling results and investigating their adequacy and accuracy. The obtained results of the research on the accuracy of modeling the full-scale tests of premises with fire in a three-story building revealed that the error, determined when comparing experimental and calculated data, was not significant. A relative error did not exceed 28%, and root-mean-square deviation did not exceed 51 °C. This means that the modeling results are adequate, which allows to use this approach for predicting the behavior of building structures in a fire under realistic conditions.uk_UA
dc.language.isoenuk_UA
dc.publisher-uk_UA
dc.relation.ispartofseriesLNCE,volume 100;-
dc.subjectComputer fire modeling Fire resistance Fire dynamics simulator PyroSim Field fire modeluk_UA
dc.titleDevelopment of a Mathematical Model of Fire Spreading in a Three-Storey Building Under Full-Scale Fire-Response Testsuk_UA
dc.title.alternative-uk_UA
dc.typeOtheruk_UA
Розташовується у зібраннях:Навчально-науково-виробничий центр

Файли цього матеріалу:
Файл Опис РозмірФормат 
Стаття – тези -скопус-2021 (LTE.docx25,2 kBMicrosoft Word XMLПереглянути/Відкрити


Усі матеріали в архіві електронних ресурсів захищені авторським правом, всі права збережені.