Будь ласка, використовуйте цей ідентифікатор, щоб цитувати або посилатися на цей матеріал: http://repositsc.nuczu.edu.ua/handle/123456789/27343
Повний запис метаданих
Поле DCЗначенняМова
dc.contributor.authorFESHCHUK, Yurii-
dc.contributor.authorNIZHNYK, Vadym-
dc.contributor.authorTSYHANKOV, Andrii-
dc.contributor.authorMELNYK, Valentyn-
dc.contributor.authorSHARIPOVA, Dariya-
dc.date.accessioned2025-12-18T13:56:39Z-
dc.date.available2025-12-18T13:56:39Z-
dc.date.issued2025-
dc.identifier.citationInstitute of Scientific Research on Civil Protection of the National University of Civil Protection of Ukraine, 60 Centralna St., Dmytrivka village, Buchanskyi district, Kyiv region, Ukraine, 2025.uk_UA
dc.identifier.urihttp://repositsc.nuczu.edu.ua/handle/123456789/27343-
dc.description.abstractThe need to study the fire hazard of typical premises of a mobile communications base station was substantiated, in particular, regarding the feasibility of equipping it with an automatic (self-contained) fire-fighting system. Criteria for assessing the fire hazard of a mobile communications base station were developed. It was experimentally established that the greatest fire hazard in the premises of a mobile communications base station was related to the following devices: Alarm Box switching panel, input and distribution board, internal air conditioner unit and 12 V 100 A#2 batteries. Moreover, the latter two ones contribute to the spread of fire inside the premises. During the ignition of the 12 V 100 A#2 batteries, it was established that the surface of the outer wall further heated to a temperature of 80 °C, which did not exceed the critical one. Thus, the fire did not spread beyond the premises. It was established that equipping the premises of a mobile communications base station with a fire-fighting system in order to prevent the fire spreading beyond its boundaries was unreasonable.uk_UA
dc.language.isoenuk_UA
dc.subjectfire hazarduk_UA
dc.subjectfire-fighting systemuk_UA
dc.subjectpremises of a mobile communications base stationuk_UA
dc.subjectflame propagationuk_UA
dc.subjecttemperatureuk_UA
dc.titleStudying Fire Hazard of Premises of a Mobile Communications Base Station.uk_UA
dc.typeArticleuk_UA
Розташовується у зібраннях:Кафедра пожежно-рятувальної та фізичної підготовки

Файли цього матеріалу:
Файл Опис РозмірФормат 
Studying_Fire_Hazard_of_Premises_of_a_Mobile_Commu.pdf1,55 MBAdobe PDFПереглянути/Відкрити


Усі матеріали в архіві електронних ресурсів захищені авторським правом, всі права збережені.