Назва: | Methodology for assessment of the fire-resistant quality of reinforced-concrete floors protected by fire-retardant coatings |
Автори: | Отрош, Юрій Анатолійович Kovalov, Andrii Kovalevska, Tatiana Safronov, Oleg |
Ключові слова: | reinforced-concrete floors fire-resistant quality |
Дата публікації: | 2019 |
Видавництво: | IOP Conf. Series: Materials Science and Engineering 708 (2019) 012058 |
Короткий огляд (реферат): | In the work, the tests have been analysed for fire-resistant quality of hollow-core reinforced-concrete floors with fire-retardant plaster covering. A two-dimensional physical model and computer model have been developed in the ANSYS FLUENT software environment, which includes a system of equations and boundary conditions, taking into account the thermal conductivity in the coating and concrete, as well as complex convection-radiation heat transfer in air voids. A one-dimensional multilayer mathematical model has been developed, equivalent to a two-dimensional model of the thermal state of hollow-core reinforced-concrete floor with fire-retardant plaster covering, with the specific these layers’ thicknesses. A methodology has been developed in the article, based on solving the direct and inverse heat conduction problems, with the help of which it is possible to assess the fire-resistant quality of hollow-core reinforcedconcrete floors with and without fire-retardant coatings. The developed methodology was applied to determine the thermophysical (heating constant and specific heating capacity per unit volume) and fire-retardant characteristics of the studied plaster covering according to the results of tests for fire-resistant quality of reinforced-concrete floors with this fire-retardant coating. The conclusion was made about the effectiveness of this coating and the boundaries of using the fireretardant coatings to ensure normalizable values for the limit of the fire-resistant quality of hollow-core reinforced-concrete floors. |
URI (Уніфікований ідентифікатор ресурсу): | 10.1088/1757-899X/708/1/012058 http://repositsc.nuczu.edu.ua/handle/123456789/11052 |
Розташовується у зібраннях: | Кафедра пожежної профілактики в населених пунктах |
Файли цього матеріалу:
Файл | Опис | Розмір | Формат | |
---|---|---|---|---|
Kovalov_2019_IOP_Conf._Ser.__Mater._Sci._Eng._708_012058.pdf | 904,09 kB | Adobe PDF | Переглянути/Відкрити |
Усі матеріали в архіві електронних ресурсів захищені авторським правом, всі права збережені.