Title: | Factors which define the α/γ ratio in CsI:Tl crystals |
Authors: | Kudin, Alexander M. Sysoeva, Elena P. Sysoeva, Elena V. Trefilova, Larisa N. Zosim, Dmitry I. |
Keywords: | Scintillator CsI:Tl Light yield Activator concentration Scintillation prosess |
Issue Date: | 2005 |
Publisher: | Elsevier Press |
Citation: | Nuclear Instruments and Methods in Physics Research A537 (2005) 105-112 |
Abstract: | Dependences of light yield and α/γ ratio on the Tl concentration have been studied within a wide range of shaping times. It is shown that the α/γ ratio essentially depends on the Tl concentration. Proper combination of the Tl concentration and optimum shaping time in electronics allows to obtain detectors with rather high light output for γ-rays, α-particles and α/γ ratio values. It has been shown that both the light yield at α-excitation and the α/γ-ratio depend on the time of crystal storage after polishing. On the basis of the idea of the formation of deformation-induced point defects in a thin surface-adjacent layer, the causes of the temporary increasing in light yield for α-particle are explained. An explanation is given of the results obtained by Gwin and Murray concerning the fact that the α/γ ratio is practically independent on Tl concentration. |
URI: | http://repositsc.nuczu.edu.ua/handle/123456789/4721 |
Appears in Collections: | Кафедра фізико-математичних дисциплін |